Available times may vary by location. %%EOF A Florida licensed contractor is required for the construction of new buildings, alteration, repairs and additions to existing buildings. Web200 Amp Meter Pole Installation 100 Amp Meter Pole Installation 60 Amp Temporary Pole Installation Conduit Installation for 3 Phase Open Delta 120/40 Volt Transformer 3 Phase Transformer Pad Installation C.T. WebGet power turned on and projects underway. Our service crews will hook up the temporary pole. Do keep in mind this is a separate account from the one you may use on FPL.com. After submitting your application, you can track the status of your project from your project dashboard. Temporary Permanent Power Inspection Requirements This is an attempt to allow electrical contractors to use air-conditioning equipment only in new-house construction after sheet rock is installed. Appointments may be scheduled Monday to Friday between the hours of 9:00 a.m. to 2:00 p.m. Service upgrades, overhead to underground service conversions, disconnect/reconnect appointments or standby work Florida Administrative Code. APPLICATIONS MUST BE SIGNED BY AN AUTHORIZED AGENT OF THE CONTRACTOR AND MUST BE NOTARIZED. To learn about the project life cycle process for overhead to underground conversion, view project types. Required for any repairs or installation of roofing which exceeds 100 square feet of area. For Your Please let us know as soon as possible, so the service can be dug and ready before you get your final inspection. The phase of a work request defines the status of the work request and lists specific actions and requirements. The meter can and downpipe have been installed. Temporary Construction Pole Electric Service Requirements 60 200 AMP Capacities, 120/240-Volt Single-Phase A. ATTACHMENT: The customer must provide point of attachment at the top of the pole. Either an eyebolt or a J-hook is acceptable and must be within the top 6 inches of the pole (12 feet above ground). B. While the checklists are thorough, they are not exhaustive and do not apply to every permitted project type. The standby power supply shall be capable of operating the emergency responder radio coverage system for a duration of The easement must be executed and recorded prior to the start of construction. You can track the status of your project from your project dashboard. Meter Can and Cabinet C.T. TO: Tambre Lee, Building Official . WebStep 1: Apply for a building permit. Common project members are: All documents related to a project or work request are visible on the Documents/Photos Tab on the Project and Work Request pages. However, FPL may agree to provide a second voltage if: For additional information, check with your local inspecting authority and FPL Project Manager. hb``g``Nf`a` @q/!(p#^00u A)*``HKXS?XI )bLs8p{ Adding a project to your dashboard provides an easy way to access and work with your projects. If you are building a new home, CHELCO and Southland Utility Servicesare here to help you as you coordinate your electricity to your site. To request a disconnect or reconnect, submit a project application. Underground Residential Service Policy Development FPL defines the specific work needed to complete your project. WebAluminum Vinyl or Acrylic Panels Installation Certificate Electrical Electrical Inspection for Power Release Pre-Final Electrical Service Application Holiday, Weekend, Night Emergency Electrical Form Temporary Underground Electrical Service (TUG) Agreement Permitting Permit Application Permit Authorization / Sign On If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. Once these have been approved the final covering may be installed and a final roof inspection scheduled. View PDF. The electrical line that connects the property to FPLs electric system, however, does not require an easement. Electrical contractors are not allowed to reconnect the electric service. Powerful service at your fingertips--wherever you go! To learn about the project life cycle process for disconnect and reconnect jobs, view project types. 200 Amp Meter Pole Installation Plan & Design During this phase, you and FPL will plan the scope of the work and FPL will complete the design of their facilities. Please review our Privacy Policy for additional details. endstream endobj startxref 0 Paymentcan be made onlineor by check or money order to:Please submit to:Tampa Electricc/o ED BillingPO Box 173169Tampa, FL 33672, Tampa Electric is an Emera company. WebAPPLICATION FOR TEMPORARY POWER POLE INITIAL SUBMITTAL WILL INCLUDE THE FOLLOWING ITEMS If any submittals do not meet these requirements, they will 1-16 Location of non-oil filled electrical equipment. WebStep 1: Apply for a building permit. For example - panel A, panel B, main circuit breakers, main panels, etc. During the lifecycle of your project you may have to pay a construction invoice. WebTemporary Permanent Power Inspection Requirements Inspection requirements: All grounds must be terminated in panels. hbbd```b``^`)d"dICTN7E~e"`}ze "S"! You can also contact a construction office near you. endstream endobj 133 0 obj <>/Metadata 19 0 R/OCProperties<>/Outlines 42 0 R/PageLayout/OneColumn/Pages 130 0 R/StructTreeRoot 47 0 R/Type/Catalog/ViewerPreferences<>>> endobj 134 0 obj <> endobj 135 0 obj <>stream Required when any new piping, re-piping, fixtures are added, including backflow devices. C.T. Right Tree and planting it in the Right Place, Include at least one letter and one number, Exclude spaces or special characters (- & / # , etc.). As of August 1, 2021, CHELCO no longer providesFlorida Energy Efficiency Code Compliance calculations. Learn more about easements. Rough-In Inspection (200): To be made after all electrical boxes and rough wiring is installed. Download a wiring diagram in Adobe PDF format here. Learn more about therates, rules and regulation and other informationas approved by the Florida Public Service Commission. After submitting your application, you can track the status of your project from your project dashboard. (850-891-7001 option 2): After all inspections are finished a C.O. Web6051 Old Bagdad Highway, Suite 202| Milton, Florida 32583 . Temporary Power Use of electricity for a temporary use, including but not limited to weekend events, holiday associated sales, and uses approved through the Temporary Use process. It may take 2 - 3 days before you are contacted due to workload. will be issued. In an action brought under this part, proof of the sale or lease, or offering for sale or lease, of any such structure by the owner-builder within 1 year after completion of same creates a presumption that the construction was undertaken for purposes of sale or lease. Replacement of a window(s) and/or a door(s) is considered structural and will require a permit. FPLs standard fees for installing electric service for new construction projects are based on overhead facilities. This question may be too broad for this format. There's no "Temporary power pole requirements" section in the NEC. Basically, you build the pole to the utilities specifications, and follow NEC while you do it. If the receptacles are exposed to weather, then you'll need in-use covers. The actual installation timeframe will vary, but is typically between 10 to 15 business days after FPL is notified that the site is ready for installation. There you will find a link to Invite Member. 2023 Choctawhatchee Electric Cooperative (CHELCO). This may include finalizing work schedules, completing necessary agreements and confirming job site readiness. Certificate of Occupancy (C.O.) All non-terminated, branch-circuit, current-carrying conductors must be terminated with wire nuts. As a regulated utility, FPL's rates, rules and regulations are approved by the Florida Public Service Commission (FPSC). You and your electrical contractor are responsible for installing the service entrance wiring at your home or business. Be sure to have a certified line-clearing specialist maintain the vegetation away from the electrical equipment and lines. The local inspecting authority approves the installation. If your service is OVERHEAD, this may be 2 or 3 working days after the engineering representative releases the job. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. Service entrance equipment shall be in a location which is accessible and Project Members should be anyone on your team who needs to receive updates on FPLs work in relation to project completion. Copyright 1996 - 2023, Florida Power & Light Company. Transformer Placement in Underground Subdivisions All of the related work requests can be viewed when tracking and managing your project. click here, Converting Condominium Lanai to Living Space, Sprinkler / Alarm Building Plan Requirements, Hazard Mitigation and Local Mitigation Strategy, Historical Building Permit Application Form, CO, TCO or CC REQUESTS - (active permits only), Online Payments for Old Paper Permits Only. With Duke Energys Builder Portal, you have the tools you need to get it done, right at your fingertips. Congratulations, you are now a member and owner of CHELCO! ), Single Phase Overhead Service Entrance (200 Amp or Less) WebSingle phase temporary power poles Overhead and underground services available Standard 125 amp-larger services available upon request Licensed electricians perform all temporary power pole installations FEMA trailer electrical hook ups Temp. Please follow these guidelines to help us provide new service when you need it. 435 N. Macomb Street An FPL Project Manager must approve your site prior to FPL beginning construction. This tab is located on the right side of the page below the members tab. When there are the appropriate power lines, transformers or other equipment at the site, FPL can install temporary electric service for a fee. Listed below are the typical inspections required for residential construction along with inspection codes and the phone numbers to call. An FPL Project Manager may need to contact you to verify the type of service that you need or address other issues, such as a certificate of occupancy, deposit requirement or inspection. Construction FPL will work to complete the scope of the work request. No permit is required for the installation of window A/C units. When your temp pole is in place, call the county and have them inspect it. WebIn the eventattachment, with that new, any willSpace temporarilyAttachmentsAttachment be required uponfrom upon thesaid notice fromused for Reserved notice from SpaceCenterPointAttachments is needed CNP upon shall 45-daysEnergy deem to prior the rearrange,notice remove You may review a sample copy of a residential permit application as a PDF, which also includes submittal requirements. WebStandby power shall be provided for emergency responder radio coverage systems required in Section 917 and the Florida Fire Prevention Code. WebThe service equipment shall satisfy all the requirements of the NEC, the building code, and the inspecting authority. Generally, if an appointment occurs during business hours, there is no cost. Mechanical Permit: Step 5: CHELCO will prepare your project for construction Step 3: If temporary power is needed, easements may be needed and construction Step 2: Apply for new electric service and get a project ID. What are the construction codes enforced by the City of Tallahassee? %PDF-1.7 % I am o9dL:b7Z"$ e`qAAg` View PDF. Before we can begin installation, we will need verification of the following: Please contact FPL several weeks before installing sod or sprinkler systems to minimize repairs. Whenever we ask you to send personal and confidential information over the internet, we first establish a "secure session" using encryption technology. Change in Service Requirements, Page 11 of 12). Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. Request electric servicefor your residence, facility or to a temporary pole. Apply for new CHELCO service onlineor at one of our area offices. To request an upgrade or relocate your existing service, submit a project application. Step 2: Apply for new electric service and get a project ID. To learn about the project life cycle process for service upgrades or relocations, view project types. For wiring diagrams not listed here, contact our engineering department at (251) 989-6247. Keep in mind card colors will vary depending on the type of request you are looking at: Projects, Work Requests, Appointments, etc. All panel covers must be installed and all disconnects installed. WebTemporary Power Pole Permit ALL APPLICATIONS SHALL BE SUBMITTED USING THE ONLINE PORTAL https://www2.citizenserve.com/waltonplanning PLEASE BE ADVISED Roofing Permit: Navigate to the Project and Work Request pages and select the Members section on the right. https://www.myfloridalicense.com/wl11.asp. INCOMPLETE APPLICATIONS WILL Some voltages may require a fee. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. View frequently asked questions about deposits. Required for any new construction, additions, alterations, or repairs with an estimated cost of labor and material greater than $2500 or is structural (to include installing, removing, or repairing any wall or partition). This work must be performed by FPL after receipt of the electrical inspection. Electric Service Standards. and withholding tax and provide workers' compensation for that employee, all as prescribed by law. An inspection is required for all new electric service installations and when FPL disconnects service for an electrical contractor to work on your electric equipment. Electrical Permit: Underground Primary Policy Outline No other circuit breakers can be installed. Youll need to provide the users Email, Name, and Role for the project. This may take 2 or 3 working days after the inspection is received. WebTemporary Pole (500): If electrical power from the house cannot be used and temporary construction power is required, the temporary service pole must be inspected prior to the service being connected. 8. However, FPL may agree to provide a second point of service if: A maximum of three weatherheads with four conductors (1,000 KCMIL conductor size maximum) in each weatherhead is allowed at every service point. For example - high voltage, danger high voltage, etc. Only the circuit breakers for the condensing units and air handlers should be installed and connected using permanent-installation wiring methods. 1-17 Location of oil filled pad-mounted equipment (2 of 2) Spec. This is the final step. Pre-Construction During this phase, you and FPL will finalize the activities needed for FPL to start working. All KOs in panels, unused circuit-breaker openings and any other openings not listed here must be blanked off in an National Electric Code (NEC)-approved method. Single Phase Underground Service (400 Amp) When you submit an application, your project is created. CHELCO's annual charity golf tournament raised over $8k, CHELCO powers-up first co-op solar array in NW Florida. Sign up to get storm preparedness and savings tips. Please check with your local inspecting authority for specific requirements and restrictions. WebThe Temporary Construction Power service must be installed in conformance with the National Electrical Code and Florida Power and Light electrical service standards (see No other 240-volt or double-pole circuit breakers (other than air-conditioning circuit breakers) should be installed. When there are the appropriate power lines, transformers or other equipment at the site, FPL can install temporary electric service for a fee. To request temporary service, submit a project applicationfor temporary power. An FPL Project Manager will be assigned within two days. You can track the status of your project from your project dashboard. You can track the status of your project If your service is underground, the 3" Schedule 80 riser pipe must be installed from the meter base past the footer to 30" below final grade. Southland Utility Services (850) 307-1183, which has been contracted for many years to provide this service to CHELCO, will continue to be available to provide fee-based code calculations directly to builders. Even though this is a temp pole, it is still a service and grounding is required by Article 250. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. WebELECTRICAL POWER POLE DIAGRAM FOR MOBILE HOMES AND RESIDENTIAL SERVICES ALL WORK SHALL COMPLY WITH THE 2014 NATIONAL ELECTRICAL PLEASE NOTE: Each construction trade requires its own permit. Be sure to inform your FPL Project Manager about any schedule changes in order to avoid additional fees and ensure your projects success. If you dont know the number, contact your FPL Project Manager or the nearest FPL Construction Office. An FPL project manager will be assigned within two days. (Section III Service Provisions, I. NOTE: The Nailing and Secondary Barrier Inspections MUST be inspected and approved prior to the installation of any Final roof covering (917). All neutrals must be terminated in panels. Power Project Types Include Residential new construction RV spaces Trailer homes Camp sites All panels must be labeled. Underground facilities require additional construction and associated costs. WebA temporary construction power pole is not an approved means of energizing a building, structure, or vacant property. Renaissance Center 735 8th Street South, Naples, Florida 34102, Commission on Ethics and Governmental Integrity, Important News- Electronic Permitting. An FPL Project Manager will be assigned within two days. You can also contact a construction office near you. An FPL Project Manager will be assigned to your project within two days. WebBuilders and developers can apply for temporary or permanent electrical service with Duke Energy for single or multi-family residences. The temporary power pole shall be installed on the building site, shall include driven ground rods, and be located outside of If you added a project or work request to your dashboard you will only view the FPL Project Manager information. 3 Phase Transformer Pad Installation Any violation of the requirements will result in removal of the house meter. An FPL Project Manager will be assigned within two days. Keep in mind that project administrators can see documents labeled as confidential in the Documents tab. The local permitting agency shall provide the person with a disclosure statement in substantially the following form. Inspection requirements: Guidelines There are two tabs available on the dashboard: After you submit an application, a project will be created and automatically added to your Project Dashboard. Business, Instrument Transformer Rated Meter Sockets and CT Metering Cabinet list, Approved Metering Equipment Enclosure List, rates, rules and regulation and other information, Customer Care: Learn More. The county will notify CHELCO when it passes inspection. WebTemporary Power Disconnect An easy way to turn your power off and on Select your location Our site is customized by location. #20. Step 3: If temporary power is needed, easements may be needed and construction costs may apply. You must provide direct, onsite supervision of the construction yourself. View ourStandard Electrical Service Requirements(SESR). Check the status of If one rod meets the 25 ohm or less, then one is acceptable. FPL shall be consulted so that the Customer's primary service All rights reserved. You will need to have bank information available to submit a payment through Speedpay or you can mail in a check to the FPL mail facility as listed on your construction invoice document. Temporary Construction Pole Electric Service Requirements 60 200 AMP Capacities, 120/240-Volt Single-Phase A. ATTACHMENT: The customer must The Member section displays the name and contact details of the FPL Project Manager assigned to the project or work request. Each project can be tracked and managed using a project number. Find answers to your questions about how to use the website and manage your FPL construction projects. If you need to talk or meet with the CHELCO engineering representative, write a note on your application so that they will contact you. Easements are required when installing any electrical lines and equipment on private property. Additional Requirements (PDF) Your user ID for the FPL Project Portal is the email you used to register. During a secure session, our computer exchanges key information with your computer in order to create a private conversation that only your computer and FPLs server can understand. To upload a document, navigate to the Project and Work Request pages and select the Add Document link under the Documents/Photos tab. If a customer requests underground facilities, they must pay the cost differential. View ourGeneral Rules and Specifications. Step 5: CHELCO will prepare your project for construction. Please make sure the path is clear of anything that could prevent our crews from being able to dig. An FPL Project Manager will be assigned within two days. The dashboard organizes all of your active and completed work requests and projects in a single place, eliminating the need to search for individual work requests or projects using the track functionality. Conduit Installation for 3 Phase Open Delta 120/40 Volt Transformer Your account will be protected by your user ID and password. Sign up for weekly storm and savings tips! WebPole shall be minimum 6 round or 6x6 treated wood. However, customers are responsible for having their property and any adjacent property cleared by a line-clearing specialist, if necessary, for the initial installation of electrical equipment.